Protective earth resistance meter RMO60E

rmo60e rmo60e
quote

Overview

  • Lightweight – only 7,5 kg
  • Powerful 10 A – 60 A DC
  • Measuring range 100 µΩ – 999,9 mΩ
  • Resolution to 0,1 µΩ
  • SINGLE / CONTIN Mode
  • Mechanical protection IP43

The RMO60E is ideal for testing the protective bonding (grounding) of equipment following the standard 61010-1 IEC 2001.

The RMO60E generates true DC current with automatically regulated test ramps. During the test RMO60E ramps with increasing current before measuring and decreasing current after the measurement. This eliminates magnetic transients. After the test current has been set, pressing the &Ohm;-button starts the automatic test procedure.

The RMO60E instrument can store up to 500 measurements. All measurements are time and date stamped. Using DV-Win software a test can be performed from a PC, and the results can be obtained directly at a PC. Communication between RMO60E and PC is through USB or RS232 cable. Using DV-Win the result can be arranged as an Excel spreadsheet that can be later shown as a diagram and printed for a report.

The set is equipped with thermal and overcurrent protection. The RMO60E has very high ability to cancel electrostatic and electromagnetic interference in HV electric fields. It is achieved by very efficient filtration. The filtration is made utilizing proprietary hardware and software.

Accessories

Included accessories

  • DV-Win PC software
  • Ground (PE) cable
  • USB cable
Recommended accessories

  • Current cables 2 x 5 m 10 mm2 with battery clips
  • Sense cables 2 x 5 m with alligator clips
  • Cable bag
Optional accessories

  • Built-in thermal printer
  • Thermal paper roll
  • Test shunt 600 A / 60 mV
  • Current cables 2 x 10 m 10 mm2
  • Sense cables 2 x 10 m with alligator clips
  • Cable plastic case

 

Technical data

Mains Power Supply
  • Connection
according to IEC/EN60320-1; C320
  • Mains supply
90 V – 264 V AC
  • Frequency
50/60 Hz
  • Fuse
12 A / 250 V, type F
Output data
  • Test current
10 A – 60 A DC
  • Full Load Voltage
    *At 230 V of supply voltage
12 V DC at 60 A
Measurement
  • Resistance range
100,0 µΩ – 999,9 µΩ
  • Resolution
    • 100 µΩ – 999,9 µΩ
    • 1,000 mΩ – 9,999 mΩ
    • 10,00 mΩ – 99,99 mΩ
    • 100,0 mΩ – 999,9 mΩ
  •  
    • 0,1 µΩ
    • 1 µΩ
    • 10 µΩ
    • 0,1 mΩ
  • Typical accuracy
± (0,1 % rdg + 0,1 % FS)
Display
  • Display
LCD screen 20 characters by 4 lines; LCD display with backlight, visible in bright sunlight
Interface
  • Interface
RMO60E is equipped with an USB port (optional: RS232) to connect to an external computer
Test Result Storage
  • Test Result Storage
RMO60E can store up to 500 measurements
Environment conditions
  • Operating temperature
–10°C – +55°C / 14 F – 131 F
  • Storage and transportation
–40°C – +70°C / -40 F – 158 F
  • Humidity
5 % – 95 % relative humidity, non condensing
  • Installation/overvoltage category
II
  • Pollution degree
2
Dimensions and Weight
  • Dimensions
198 mm x 255 mm x 380 mm
7,8 in x 10 in x 15 in
  • Weight
7,5 kg / 16,5 lbs
Warranty
  • Warranty
three years
Safety

  • Low Voltage Directive 2014/35/EU (CE Conform)

  • Applicable standards, for a class I instrument, pollution degree 2,
       Installation category II : IEC EN 61010-1

  • CAN/CSA-C22.2 No. 61010-1

Electromagnetic Compatibility

  • Directive 2014/30/EU (CE Conform)

  • Applicable standard EN 61326-1

DV-Win

RMO DV-Win Software provides several advanced features as a supplement to multiple functions of RMO devices. Testing in Continuous mode is upgraded with a sample time feature which allows user to record test results in specific time intervals set in seconds. After performed measurements results can be saved in a various formats and test report can be generated and saved or printed. Result can also be downloaded from the device to the PC by use of several different search filters.

For the RMO form of DV-Win software there is Help menu available, with detailed instructions and explanations of all functions and features.

Download


Download brochure


Version: 301
Published: 2016-05-11

Back To Top