Micro Ohmmeters – RMO-D series

rmod rmod
quote


Overview

RMO-D series contain 3 models of powerful and lightweight micro ohmmeters:

       RMO200D – test current from 5 to 200 A, weighs only 9 kg / 20 lbs
       RMO500D – test current from 5 to 500 A, weighs only 12 kg / 26.5 lbs
       RMO600D – test current from 5 to 600 A, weighs only 12 kg / 26.5 lbs
  • Measuring range: 0,1 μΩ – 999,9 mΩ
  • Resolution: 0,1 μΩ
  • Typical accuracy: ± (0,1 % rdg + 0,1 % FS)
  • Remote Control Unit (optional)
  • Both Sides Grounded Unit (optional)
  • SINGLE / CONTIN / BSG / DTRtest modes
  • DEMAGNETIZATION feature

RMO-D series of Micro Ohmmeters (hereafter referred to as “RMO-D”) is based on a state of the art technology, using the most advanced switch mode technique available today. RMO-D generates a true DC ripple-free current with automatically regulated test ramps. During a test the RMO-D ramps with increasing current before measuring and decreasing current after the measurement. This eliminates magnetic transients.

The RMO-D instrument can store internally up to 500 measurements. All measurements are time and date stamped. Using the DV-Win software a test can be performed from a user’s PC, and the results can be obtained directly on the PC. Communication between the RMO-D and a PC is through an USB (as standard) or an RS232 cable (as an option). Bluetooth communication interface is also available as an option. Using the DV-Win the result can be arranged as an Excel spread-sheet which can be later shown as a diagram and printed for a report.

The set is equipped with a thermal and an overcurrent protection. The RMO-D has a very high ability to cancel electrostatic and electro-magnetic interference in HV electric fields. It is achieved by very efficient filtration. The filtration is made utilizing a proprietary hardware and software.

The RMO-D instrument has four separate test modes:

  • SINGLE mode
  • CONTIN mode
  • BSG mode (Both Sides Grounded)
  • DTRtest mode (Dead Tank Resistance)

The DEMAGNETIZATION feature enables for full automatic demagnetization of a current transformer core after the measurement.

Accessories

Included accessories

  • Mains power cable
  • DV-Win PC software
  • Ground (PE) cable
  • USB cable
Recommended accessories

  • Current cables 2 x 5 m (16.4 ft.),       XX* mm2 with battery clips
  • Sense cables 2 x 5 m with alligator clips
  • Transport case
Optional accessories

  • Built-in thermal printer
  • Thermal paper roll
  • Test shunt 600 A / 60 mV
  • Current cables 2 x 10 m XX* mm2
  • Current cables 2 x 15 m XX* mm2
  • Extension cable 2 x 10 m XX* mm2
  • Sense cables 2 x 10 m with alligator clips
  • Sense cables 2 x 15 m with alligator clips
  • Cable plastic case
  • Cable bag
  • Remote control unit
  • Current clamp 30/300 A power supplied from the instrument with extension 5 m (Both Sides Grounded Unit)

 

XX* recommended cross-section

Model / Cable length 5 m / 16.4 ft. 10 m / 32.8 ft. 15 m / 49.2 ft.
RMO200D 25 mm2 (4 AWG) 25 mm2 (4 AWG) 35 mm2 (2 AWG)
RMO500D 50 mm2 (1/0 AWG) 50 mm2 (1/0 AWG) 70 mm2 (2/0 AWG)
RMO600D 50 mm2 (1/0 AWG) 50 mm2 (1/0 AWG) 70 mm2 (2/0 AWG)

Technical data

Mains Power Supply

  • Connection: according to IEC/EN60320-1; C320
  • Mains supply: 90 V – 264 V AC
  • Power consupation:
  • @ 230 V AC of supply voltage

    RMO200D RMO500D RMO600D
    1786 VA 3866 VA 4560 VA

    @ 115 V AC of supply voltage

    RMO200D RMO500D RMO600D
    1769 VA 3615 VA 3927 VA
  • Fuse:
  •    RMO200D     12 A / 230 V, type F
       RMO500D     15 A / 230 V, type F
       RMO600D     20 A / 250 V, type F

Output data

  • Test current
  • RMO200D RMO500D RMO600D
    5 – 200 A 5 – 500 A 5 – 600 A
  • Max load interval (@ I max)
  • RMO200D RMO500D RMO600D
    150 s 30 s 20 s
  • Full Load Voltage*
  • @ 230 V AC of supply voltage

    RMO200D RMO500D RMO600D
    6,70 V 5,80 V 5,70 V

    @ 115 V AC of supply voltage

    RMO200D RMO500D RMO600D
    6,70 V 4,70 V 3,60 V

    *maximal output voltage at maximal test current

Measurement

  • Resistance range: 0,1 µΩ – 999,9 mΩ
  • Resolution
    •    0,1 µΩ – 999,9 µΩ            0,1 µΩ

         1,000 mΩ – 9,999 mΩ     1 µΩ

         10,00 mΩ – 99,99 mΩ     10 µΩ

         100,0 mΩ – 999,9 mΩ      0,1 mΩ

  • Typical accuracy: ± (0,1 % rdg + 0,1 % FS)
Environment conditions

  • Operating temperature:       -10°C – +55°C / 14°F – 131°F
  • Storage and transportation: -40°C – +70°C / -40°F – 158°F
  • Humidity: 5 % – 95 % relative humidity, non condensing
  • Installation/overvoltage category: II
  • Pollution degree: 2
Dimensions and Weight

  • Dimensions: 405 mm x 165 mm x 330 mm
                             15.94 in  x   6.5 in    x   12.99 in
  • *RMO200D without built-in thermal printer

  • Dimensions: 480 mm x 190 mm x 385 mm
                             18.90 in  x   7.48 in    x   15.16 in
  • **RMO500D, RMO600D and for RMO200D with built-in thermal printer

  • Weight
  • RMO200D RMO500D RMO600D
    9 kg / 20 lb 12 kg / 26.5 lbs 12 kg / 26.5 lbs
Warranty

  • Warranty: three years
Data storage and transfer

  • Internal memory locations: 500 result sets
  • Connection Interface:
  •    USB serial interface to connect to an external computer,
       or RS232 interface (optional),
       Bluetooth communication module (optional) – works in combination with RS232 interface.

Printer (optional)

  • Thermal printer: Paper width 80 mm
Safety

  • Low Voltage Directive 2014/35/EU (CE Conform)
  • Applicable standards, for a class I instrument, pollution degree 2,
       Installation category II : IEC EN 61010-1
  • CAN/CSA-C22.2 No. 61010-1
Electromagnetic Compatibility

  • Directive 2014/30/EU (CE Conform)
  • Applicable standard EN 61326-1

All specifications listed herein are valid at the ambient temperature of + 25 °C (77°F) and with the recommended accessories included.

Specifications are subject to change without notice.

DV-Win Software


dv-win


  • Full control of the device in test
  • Test raports available in several formats
  • Several filters for results download to a PC
  • Test plans
  • Samling time feature for CONTIN mode
  • Detailed Help menu

*included in the purchase price



RMO DV-Win Software provides several advanced features as a supplement to multiple functions of RMO devices. Testing in Continuous mode is upgraded with a sample time feature which allows user to record test results in specific time intervals set in seconds. After performed measurements results can be saved in a various formats and test report can be generated and saved or printed. Result can also be downloaded from the device to the PC by use of several different search filter.

For the RMO form of DV-Win software there is Help menu available, with detailed instructions and explanations of all functions and features.

Download


Download brochure


Version: 305
Published: 2017-04-06

Back To Top